BESTMAN Portable Fetal Monitor With Thermal Printer

BESTMAN Portable Fetal Monitor With Thermal Printer

J MED

  • Dhs. 5,889.00
    Unit price per 
Tax included. Shipping calculated at checkout.


FREE EXPRESS DELIVERY TO YOUR ADDRESS IN UAE

 

Disclaimer: This item may be intended for use by healthcare professionals only.

 

Product: Ultrasound Fetal Maternal Monitor with Thermal Printer

HTB1mfc9LVXXXXatapXXq6xXFXXXX

Main components:

main unit、power cables、Transducer ( US transducer、UC transducer,   SpOtransducer)、fetal movement marker cable ,thermal array recorder and communication interface.

Functions:

The unit can monitor fetal heart rate, fetal movement, TOCO, SpO

It assembling parameter measurement module function, display and output into one whole, form a compact and portable monitor.

TFT LCD double-interface displayed FHR with the curve, maternal TOCO and SpOwith the curve, Pulse Rate, at the same time FHR curve, TOCO curve and other data can be printed out by the inside thermal printer .

Applicable scope: used to detect the fetal heart rate, pregnant woman’s TOCO, SpO2  pulse rate in hospital.  

Features:

The unit supplies two kinds of power: Inside Ni-NH rechargeable battery and A/C adapter. It can work in AC condition as well as to charge the battery. After full charge, the unit can supply the power with inside battery supply. Measurement parameters

Specifications:

Comprehensive Sensitivity: ≥90dB

Isptp:≤ 1Mpa

Adapter Input Voltage:AC 110V-240V  50Hz ±1 Hz

Adapter Output Voltage(no load):DC 24V±2V

Input power(working under charging):≤ 20VA

Ultrasonic work frequency:1.0 MHz±10% 

Heart Rate Detecting range:50 BPM—240 BPM

Heart Rate alarm upper limit:55 BPM—240 BPM resolution is 5bpm

Heart Rate alarm lower limit: 50 BPM—235 BPM  resolution is 5bpm

Print  Resolution:27 bpm/ cm

TOCO:

Detecting Range:0~100 100units  (non-linear error: ≤±10%)

Print Resolution 40Uunit / cm

THERMAL RECORDER

Print speed ( adjustable ): 01cm/min,02cm/min,03cm/min

Recorder paper speed Accuracy is ±5%

Pulse SpO2:                          

Measuring range (0 ~ 100)%;

Measuring accuracy: between (70-100) is ±2 %

Between (50-69) is ±3 %

SpO2 alarm upper limit setting:(000-100)

SpO2 alarm lower limit setting:(000-100)

PR

Measuring range:(30 ~ 250)bpm

Measuring accuracy:

±1BPM or ±2%,Minimax value.

PR alarm upper limit setting(000-255)

PR alarm lower limit setting:(000-255)

Built-in Battery: 14.4V Ni-MH rechargeable batteries ( User can not change it at discretion

Battery working time: > 4 hours (intermittent duty )

Static state work time: > 8 hours ( after full charge)

Audio Output Power: ≥1.8 W

Doppler Frequency:100—5000 Hz 

Adapter

Input pressure:AC 110V-240V  1A  50Hz ±1 Hz

Output pressure:(no load)DC 24V±2V

Input power(working under charge):≤ 20VA

 

HTB1VeLVLXXXXXaIXXXXq6xXFXXX4HTB1oRPLLXXXXXbTXpXXq6xXFXXXr